Insulation Calculator
Work out how much loft, attic, wall or floor insulation to buy. Enter the area, the R-value you want to reach, the R-value of one layer of the product and the coverage per pack or roll. The calculator finds how many layers you need, the R-value you will achieve in US R and metric RSI, and the number of packs or rolls including waste.
Insulation calculator
On this calculator: Ctrl+Enter copies the result, Shift+Alt+L copies a link to the current inputs, Shift+Alt+R resets, Shift+Alt+P opens Print / Save PDF. These shortcuts do not run while you type in a field, except Ctrl+Enter.
Saved results on this device
Stored only in this browser, not on our servers.
How to use the insulation calculator
- Measure the area. For a loft or attic floor, measure the floor area between the walls. For walls, multiply length by height and subtract openings.
- Enter the target R-value. Use the recommendation for your climate zone or the value your building rules require. US users enter R; metric users enter RSI (m²K/W).
- Enter the product's R-value and coverage. Read the R-value or RSI and the coverage per pack or roll from the label.
- Add waste. About 5% covers trimming around joists, pipes and hatches.
Insulation is specified by its thermal resistance: the higher the R-value, the better it slows heat flow. Building rules and energy programs recommend a target for each part of the home. This calculator turns that target into a shopping list of layers and rolls or packs.
The formula explained
Layers = ⌈ Target R ÷ R per layer ⌉
Achieved R = Layers × R per layer
Packs = ⌈ Area × Layers × (1 + Waste ÷ 100) ÷ Coverage per pack ⌉
RSI = US R × 0.1761 | US R = RSI × 5.678
R vs RSI. US and Canadian product labels often show R-values in imperial units (ft²·°F·h/BTU); Canadian labels also show RSI. UK, European and Australian products use RSI (m²K/W), or give thickness and thermal conductivity (λ). The calculator handles both: switch units to enter RSI.
From thickness and λ. If a product only lists thickness and λ (lambda), RSI = thickness (m) ÷ λ. A 100 mm roll with λ 0.044 W/mK has RSI 2.27.
Worked examples
Example 1: US attic
1,000 ft² of attic floor, target R49, batts of R30 per layer in 40 ft² packs, 5% waste:
- Layers: 49 ÷ 30 = 1.63 → 2 layers, achieving R60 (RSI 10.57).
- Area to cover: 1,000 × 2 = 2,000 ft², or 2,100 ft² with waste.
- Packs: 2,100 ÷ 40 = 52.5 → 53 packs (50 without waste).
Using an R19 product between joists and R30 across the top would give R49 exactly; to model that, run the calculator once for each layer.
Example 2: UK loft top-up to 270 mm
A 40 m² loft, mineral wool λ 0.044 in 100 mm rolls covering 8.3 m², target 270 mm (RSI 6.14):
- RSI per layer: 0.1 ÷ 0.044 = 2.27.
- Layers: 6.14 ÷ 2.27 = 2.7 → 3 layers (300 mm), achieving RSI 6.82.
- Rolls: 40 × 3 × 1.05 ÷ 8.3 = 15.2 → 16 rolls.
In practice, UK loft rolls are often sold in 100 mm and 170 mm thicknesses so that 100 + 170 = 270 mm.
Loose-fill insulation
Blown or poured loose-fill insulation (cellulose, loose mineral wool or fibreglass) is sold by the bag, and each bag’s label has a coverage chart showing how many bags per 1,000 ft² or per 100 m² are needed for each R-value, along with the minimum settled thickness. Because loose fill settles and its density varies by product, use the manufacturer’s chart rather than this calculator’s layer method. You can still use the area calculation here, then look up the bags-per-area figure for your target R-value on the bag.
Rigid boards
Rigid foam and mineral fibre boards are counted the same way as rolls: enter the R-value or RSI of one board thickness and the board area as the coverage. Boards are often fitted in two layers with staggered joints, which suits the layer count the calculator produces.
Regional notes: US, UK, Australia and Canada
United States. ENERGY STAR publishes recommended R-values by climate zone for attics, walls and floors. For uninsulated attics the recommendations range from about R30 in the warmest zones to R49–R60 in colder zones. Local energy codes, often based on the IECC, set legal minimums for new work.
United Kingdom. The Energy Saving Trust recommends 270 mm of mineral wool loft insulation. Building Regulations Part L sets U-values for new work rather than R-values; a U-value is roughly 1 ÷ total RSI of the whole construction.
Australia. The National Construction Code sets minimum total R-values (RSI) for roofs, walls and floors by climate zone. Product labels state R-values in metric (m²K/W), so “R4.0” in Australia means RSI 4.0, not US R4.
Canada. Natural Resources Canada publishes guidance on insulation levels, and the National Building Code and provincial codes set minimums. Labels typically show both RSI and imperial R-values.
Tips and common mistakes
- Do not compress batts or rolls; buy the right thickness for the space.
- Keep ventilation paths clear at the eaves so the roof space can breathe.
- Keep clear of recessed lights and flues unless products are rated for contact.
- Insulate the loft hatch and seal air leaks; gaps reduce performance far more than their size suggests.
- Wear protection (gloves, mask and eye protection) when handling mineral wool.
- Leave space for storage with raised loft boards rather than squashing insulation.
Related tools
Boarding over insulated walls? Use the drywall calculator. For the roof area of a pitched roof, see the roofing calculator.
Plan the rest of the project
To find the area to insulate, use the square footage calculator. For a roof space also check the roof pitch calculator, and for the timber frame holding the insulation see the lumber calculator.
Frequently asked questions
How do I calculate how much insulation I need?
Divide the target R-value by the product's R-value per layer and round up to get layers. Multiply area by layers, add waste and divide by the pack coverage.
How do I convert R-value to RSI?
Multiply US R-value by 0.1761 to get RSI in m²K/W. Divide RSI by 0.1761 (or multiply by 5.678) to get US R. R-49 is about RSI 8.6.
What R-value should my attic have?
ENERGY STAR recommends attic levels from about R30 to R60 depending on US climate zone, with R49–R60 for most of the northern US. Check the zone map for your location.
How thick should loft insulation be in the UK?
The Energy Saving Trust recommends a depth of 270 mm for mineral wool loft insulation.
Do insulation R-values add up?
Yes. When layers are stacked, their R-values add. Two layers of R30 give about R60, provided they are not compressed.
Why does compressed insulation perform worse?
Batt and roll insulation works by trapping air. Squashing it under boards or storage reduces its thickness and its effective R-value.
How do I find RSI from thickness?
RSI equals thickness in metres divided by thermal conductivity (λ, W/mK). 100 mm of insulation with λ 0.044 is 0.1 ÷ 0.044 = RSI 2.27.
Should I lay the second layer across the joists?
Commonly yes. The first layer fits between the joists and the second is laid at right angles over the top to cover the joists and reduce thermal bridging.
Related calculators
Drywall Calculator
Sheets of drywall or plasterboard for walls and ceilings.
Roofing Calculator
Roof area, squares, bundles and tiles from footprint and pitch.
Square Footage Calculator
Area of rooms and L-shapes in sq ft, m² and sq yd, with cut-outs and waste.
Paint Calculator
Gallons or litres of paint for walls and ceilings, with doors and windows subtracted.
Sources and references
About this calculator
Written and maintained by Rashid Mehmood, founder of CalcTen. The formulas are unit-tested against hand-worked examples, and the content is reviewed whenever product sizes or guidance change. Last updated and reviewed 1 November 2026. See our editorial policy. If you spot a mistake, report it.
Results are estimates for planning and ordering. Always check product labels, supplier advice and local building codes, and consult a qualified professional for structural work. Read the disclaimer.