BTU Calculator
Enter a room length and width to get a planning cooling capacity in British thermal units per hour (BTU/h), plus the same figure in tons and watts. The base size comes from the ENERGY STAR room air-conditioner chart for rooms with 8-foot ceilings. Official adjustments then raise or lower the size for shade, sun, extra people and a kitchen. This is a planning estimate, not a Manual J load calculation, and not a substitute for a qualified HVAC design.
BTU / air conditioner size calculator
On this calculator: Ctrl+Enter copies the result, Shift+Alt+L copies a link to the current inputs, Shift+Alt+R resets, Shift+Alt+P opens Print / Save PDF. These shortcuts do not run while you type in a field, except Ctrl+Enter.
Saved results on this device
Stored only in this browser, not on our servers.
How to use the btu calculator – room air conditioner size
- Enter the room size. Type the length and width. Square footage is length × width. The chart assumes about 8-foot ceilings.
- Set the sun and occupancy. Choose a shaded room (reduce 10%), an average room, or a very sunny room (increase 10%). Add people beyond two, and tick the box if the room is a kitchen.
- Read the capacity. The result shows the adjusted BTU/h, the equivalent in tons and watts, the chart band that was used, and the adjustments applied.
- Treat it as a plan, not a design. Use the figure to compare room units. A whole-house system, unusual ceilings, or a poorly insulated room needs a proper load calculation.
How the size is chosen
The floor area is length × width. That area is matched to an ENERGY STAR band (for 8-foot ceilings), which supplies a base BTU/h. Adjustments are then applied:
Area = length × width
Adjusted BTU/h = chart size × sun factor + 600 × extra people + 4,000 if a kitchen
Sun factor is 0.9 (shaded), 1.0 (average) or 1.1 (very sunny)
Tons = BTU/h ÷ 12,000 · Watts ≈ BTU/h × 0.293071
Worked examples
15 ft by 12 ft, two people, average sun, not a kitchen. Area = 180 ft², which sits in the 150–250 ft² band. The chart size is 6,000 BTU/h. No adjustments apply, so the recommendation stays 6,000 BTU/h, or 0.50 tons, about 1,758 W.
The same 180 ft² room, very sunny, four people, and a kitchen. Start from 6,000. A very sunny exposure raises that by 10% to 6,600. Two extra people add 1,200. A kitchen adds 4,000. The adjusted size is 11,800 BTU/h.
A 20 ft by 20 ft living room (400 ft²), shaded, two people. The 400–450 ft² band is 10,000 BTU/h on the chart. Shade reduces it by 10% to 9,000 BTU/h.
Use cases and common mistakes
Use the calculator to shortlist a window or portable unit, not to design a ducted system. Common mistakes include forgetting ceiling height (the chart assumes about 8 feet), counting the first two occupants as “extra people,” and treating a sunny west-facing room as “average.” If you only know the area, you can still enter any length and width that multiply to that area, or measure the room with the square footage calculator. Insulation and fabric choices belong on the insulation calculator. Electrical current and voltage questions are on the Ohm’s law calculator.
Limitations
The ENERGY STAR chart stops at 2,500 ft². It assumes 8-foot ceilings and a typical room, not a glass box, a loft or a house. Figures are a planning estimate, not a Manual J report, not an ENERGY STAR certification of a particular product, and not installation advice.
Frequently asked questions
What size AC for a 15 × 12 foot room?
The area is 180 square feet. On the ENERGY STAR chart that falls in the 150–250 ft² band, which starts at 6,000 BTU/h. With two people and average sun, the adjusted size stays 6,000 BTU/h (0.5 tons, about 1,758 W). Extra people, a very sunny exposure, or a kitchen would raise it.
Where does the chart come from?
The band-to-BTU table is the ENERGY STAR room air conditioner sizing chart (8-foot ceilings), taken from the ENERGY STAR room AC product-finder page and consistent with the 2007 ENERGY STAR Room Air Conditioner Partner Resource Guide. Sources are listed below and in the result.
What adjustments do you apply?
A heavily shaded room: reduce the chart size by 10%. A very sunny room: increase it by 10%. Each person above two: add 600 BTU/h. A kitchen: add 4,000 BTU/h. Those are the official qualitative adjustments published with the chart. The result lists which ones were used.
Is this a Manual J calculation?
No. Manual J accounts for insulation, windows, orientation, infiltration, ductwork and climate in a way this chart does not. This page is a planning shortcut for a single room unit, clearly labelled as an estimate.
How many BTU are in a ton of cooling?
One refrigeration ton is 12,000 BTU/h. Watts are converted as 1 BTU/h ≈ 0.293071 W. Those are unit conversions, not a change in the recommended size.
What if my room is smaller than 100 ft² or larger than 2,500 ft²?
The ENERGY STAR chart used here starts at 100 ft² and ends at 2,500 ft² (34,000 BTU/h before adjustments). Outside that range the calculator will not invent a number.
Is this a specification or a product recommendation?
Neither. It is a planning estimate from a published chart. Confirm the unit and the room with the manufacturer or a qualified installer.
Related calculators
Square Footage Calculator
Area of rooms and L-shapes in sq ft, m² and sq yd, with cut-outs and waste.
Insulation Calculator
Layers and packs to reach a target R-value or RSI.
Paint Calculator
Gallons or litres of paint for walls and ceilings, with doors and windows subtracted.
Ohm’s Law Calculator – Voltage, Current, Resistance and Power
Solve V, I, R and P from any valid pair, using V = I × R and P = V × I.
Voltage Drop Calculator
Volts and percent drop for AWG or mm² cable.
Sources and references
About this calculator
Written and maintained by Rashid Mehmood, founder of CalcTen. The formulas are unit-tested against hand-worked examples, and the content is reviewed whenever product sizes or guidance change. Last updated and reviewed 15 November 2026. See our editorial policy. If you spot a mistake, report it.
Results are estimates for planning and ordering. Always check product labels, supplier advice and local building codes, and consult a qualified professional for structural work. Read the disclaimer.